{"id":5560,"date":"2016-08-04T15:27:16","date_gmt":"2016-08-04T12:27:16","guid":{"rendered":"https:\/\/fuelcleaning.globecore.com\/products\/cmm-2-2-mobile-oil-plant.html\/"},"modified":"2019-12-04T12:05:37","modified_gmt":"2019-12-04T09:05:37","slug":"cmm-2-2-mobile-oil-plant","status":"publish","type":"page","link":"https:\/\/fuelcleaning.globecore.com\/fr\/products\/cmm-2-2-mobile-oil-plant\/","title":{"rendered":"CMM-2.2 MOBILE OIL PLANT"},"content":{"rendered":"<div id=\"pl-3884\" class=\"panel-layout\">\n<div id=\"pg-3884-0\" class=\"panel-grid panel-no-style\">\n<div id=\"pgc-3884-0-0\" class=\"panel-grid-cell\">\n<div id=\"panel-3884-0-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child panel-last-child\">\n<div class=\"so-widget-sow-editor so-widget-sow-editor-base\">\n<div class=\"siteorigin-widget-tinymce textwidget\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-2708\" src=\"http:\/\/fuelcleaning.globecore.com\/wp-content\/uploads\/sites\/2\/2016\/05\/\u0421\u041c\u041c-2.2.jpg\" alt=\"\u0421\u041c\u041c 2.2\" width=\"709\" height=\"768\" \/><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div id=\"pgc-3884-0-1\" class=\"panel-grid-cell\">\n<div id=\"panel-3884-0-1-0\" class=\"so-panel widget widget_sow-editor panel-first-child panel-last-child\">\n<div class=\"so-widget-sow-editor so-widget-sow-editor-base\">\n<div class=\"siteorigin-widget-tinymce textwidget\">\n<p><strong>The CMM-2.2 mobile oil unit is used for:<\/strong><br \/>1) heating electrical equipment that contains dielectric insulating oil with hot oil;<br \/>2) for vacuum drying of transformers;<br \/>3) for vacuumizing of equipment.<\/p>\n<p>The unit is best suited to facilities that install, repair and service oil filled electric power transformers and other oil filled electrical equipment.<\/p>\n<p><strong>The benefits of CMM-2.2:<\/strong><br \/>&#8211; No need any sorbents, silica gel or zeolite for\u00a0oil drying process\u00a0<br \/>&#8211;\u00a0Unit is compact, protected with metal doors, can be trailer mounted for on \u00a0field\u00a0usage<br \/>&#8211; Easy to operate and maintain,\u00a0one-man operation<br \/>&#8211; Low energy consumption, noiseless\u00a0and highly effective\u00a0<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div id=\"pg-3884-1\" class=\"panel-grid panel-no-style\">\n<div id=\"pgc-3884-1-0\" class=\"panel-grid-cell\">\n<div id=\"panel-3884-1-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child panel-last-child\">\n<div class=\"so-widget-sow-editor so-widget-sow-editor-base\">\n<div class=\"siteorigin-widget-tinymce textwidget\">\n<p>The CMM-2.2 mobile oil plant removes solid particles, water and gases from dielectric\u00a0 insulation oil.<\/p>\n<p>The plant is used for installation, repairs and operation of oil filled high voltage equipment (power transformers, high voltage switches etc).<\/p>\n<p>Operating conditions:<\/p>\n<ul>\n<li>ambient temperature from 278 to 313\u00b0\u041a (+5 to + 35\u00b0C\/ 8\u00b0F to 104\u00b0F;<\/li>\n<li>atmospheric pressure 84 to 106.7 kPa (630 to 800 mm. );<\/li>\n<li>elevation up to 2000 meters\/6561 feet above sea level;<\/li>\n<li>outdoors and under canopy;<\/li>\n<li>indoors with adequate<\/li>\n<\/ul>\n<h3>TECHNICAL SPECIFICATIONS OF CMM-2.2<\/h3>\n<table>\n<tbody>\n<tr>\n<td width=\"442\">\n<p><strong>Parameter<\/strong><\/p>\n<\/td>\n<td width=\"215\"><strong>Value<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"442\">Capacity, m3\/hour \u00a0\/ gals. per hour:<\/td>\n<td width=\"215\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"442\">\n<ul>\n<li>thermal vacuum drying mode;<\/li>\n<\/ul>\n<\/td>\n<td width=\"215\">\n<p>2.2\/582.34<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"442\">\n<ul>\n<li>degassing mode<\/li>\n<\/ul>\n<\/td>\n<td width=\"215\">\n<p>1.0\/264.7<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"442\">Processed oil parameters*:<\/td>\n<td width=\"215\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"442\">\n<ul>\n<li>mass moisture content, g\/ton, max<\/li>\n<\/ul>\n<\/td>\n<td width=\"215\">\n<p>10<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"442\">\n<ul>\n<li>filtration fineness, micron<\/li>\n<\/ul>\n<\/td>\n<td width=\"215\">\n<p>5<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"442\">\n<ul>\n<li>total gas content, % max<\/li>\n<\/ul>\n<\/td>\n<td width=\"215\">\n<p>1.5<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"442\">Max oil output temperature in heating mode, \u00ba\u0421\/ \u00baF<\/td>\n<td width=\"215\">\n<p>60\/140<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"442\">Min outlet pressure, MPa<\/td>\n<td width=\"215\">\n<p>0.2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"442\">Oil heater power, kW max<\/td>\n<td width=\"215\">\n<p>36<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"442\">Max power consumption, kW<\/td>\n<td width=\"215\">\n<p>40<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"442\">Electric power<\/td>\n<td width=\"215\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"442\">\n<ul>\n<li>voltage, V<\/li>\n<\/ul>\n<\/td>\n<td width=\"215\">\n<p>380<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"442\">\n<ul>\n<li>AC frequency, Hz**<\/li>\n<\/ul>\n<\/td>\n<td width=\"215\">\n<p>50\/60<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"442\">Dimensions, mm\/ft<\/td>\n<td width=\"215\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"442\">\n<ul>\n<li>length<\/li>\n<\/ul>\n<\/td>\n<td width=\"215\">\n<p>1550\/5\u20191\u2019\u2019<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"442\">\n<ul>\n<li>width<\/li>\n<\/ul>\n<\/td>\n<td width=\"215\">\n<p>1000\/3\u20193\u2019\u2019<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"442\">\n<ul>\n<li>height<\/li>\n<\/ul>\n<\/td>\n<td width=\"215\">\n<p>1850\/6\u20191\u2019\u2019<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><em><strong>Note:<\/strong> <\/em>* Parameters indicated in the table are possible with the<br \/>following initial conditions:<\/p>\n<p>\u2022 volumetric gas content \u2013 below 10.5%<br \/>\u2022 mass moisture content \u2013 below 0.005% (50 g\/ton)<br \/>\u2022 temperature \u2013 above 0 \u00ba\u0421\/32 \u00baF<br \/>\u2022 with initial heating of oil in the unit to +60\u00b1 5\u043e\u0421\/ 140\u00b0\u00b1 9\u043eF.<\/p>\n<p>**All equipment sold in the USA is designed to operate on 60 Hz<br \/>AC Power<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>The CMM-2.2 mobile oil unit is used for:1) heating electrical equipment that contains dielectric insulating oil with hot oil;2) for vacuum drying of transformers;3) for vacuumizing of equipment. The unit is best suited to facilities that install, repair and service oil filled electric power transformers and other oil filled electrical equipment. The benefits of CMM-2.2:&#8211;<a class=\"cg-read-more\" href=\"https:\/\/fuelcleaning.globecore.com\/fr\/products\/cmm-2-2-mobile-oil-plant\/\" target=\"_blank\">Read More <\/a><\/p>\n","protected":false},"author":2,"featured_media":0,"parent":5537,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-templates\/page-single-products.php","meta":{"footnotes":""},"class_list":["post-5560","page","type-page","status-publish","hentry"],"language":"fr","acf":[],"_links":{"self":[{"href":"https:\/\/fuelcleaning.globecore.com\/fr\/wp-json\/wp\/v2\/pages\/5560","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/fuelcleaning.globecore.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/fuelcleaning.globecore.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/fuelcleaning.globecore.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/fuelcleaning.globecore.com\/fr\/wp-json\/wp\/v2\/comments?post=5560"}],"version-history":[{"count":0,"href":"https:\/\/fuelcleaning.globecore.com\/fr\/wp-json\/wp\/v2\/pages\/5560\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/fuelcleaning.globecore.com\/fr\/wp-json\/wp\/v2\/pages\/5537"}],"wp:attachment":[{"href":"https:\/\/fuelcleaning.globecore.com\/fr\/wp-json\/wp\/v2\/media?parent=5560"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}