Fuel, oil cleaning systems
UVR fuel, oil cleaning system is intended for regeneration of transformer, turbine, industrial and other light mineral oils, cleaning, filtration and clarification, removal of acidity, products of aging and oxidation of oils.
GENERAL INFORMATION
All those examples regenerated in our installations UVR
All units of a complex on production of the fuel cleaning system UVR are made from stainless steel in following executions: general purpose industrial, containerized and explosion-proof version.
More details you can find in our product catalogue
Comparative characteristics of UVR units
# | Name of parameters | Value | |||
1 | Regeneration productivity, m³/h: | UVR-450/6 | UVR-450/16 | UVR-460/16(C) | UVR-460/16(V) |
-transformer oil | 0,1 | 0,28-0,3 | 0,28-0,3 | 0,3 | |
-turbine oil | 0,1 | 0,28-0,3 | 0,28-0,3 | 0,3 | |
-industrial oil | 0,15 | 0,28-0,3 | 0,28-0,3 | – | |
-dark heating oil (crude oil) | 0,25 | 0,6-0,8 | 0,6-0,8 | 0,6-0,8 | |
-dark diesel oil | 0,25 | 0,6-0,8 | 0,6-0,8 | 0,6-0,8 | |
-dark gasoline | 0,30 | 0,7-1,1 | 0,7-1,1 | 0,7-1,1 | |
2 | Regenerating powder consumption in % from the weight of cleaning product | ||||
-transformer oil | 3-17 | 3-17 | 3-17 | 3-17 | |
-turbine oil | 3-17 | 3-17 | 3-17 | 3-17 | |
-industrial oil | 3-17 | 3-17 | 3-17 | – | |
-dark heating oil (crude oil) | 2-15 | 2-15 | 2-15 | 5-20 | |
-dark diesel oil | 1-7 | 1-7 | 1-7 | 1-7 | |
-dark gasoline | 1-5 | 1-5 | 1-5 | 1-5 | |
3 | The weight of regenerating powder for filling | ||||
-one regeneration module, kg | 20(35) | 20(35) | 20(35) | 20(35) | |
-all regeneration modules, kg | 200(300) | 400(600) | 400(600) | 400(600) | |
4 | Loss (oil product) in % from initial volume (that that remains in a sorbent) | ||||
-transformer oil | 1-6 | 1-6 | 1-6 | 1-6 | |
-turbine oil | 1-6 | 1-6 | 1-6 | 1-6 | |
-industrial oil | 1-6 | 1-6 | 1-6 | 1-6 | |
-dark heating oil (crude oil) | 1-6 | 1-6 | 1-6 | 1-6 | |
-dark diesel oil | 1-6 | 1-6 | 1-6 | 1-6 | |
-dark gasoline | 1-6 | 1-6 | 1-6 | 1-6 | |
5 | Total capacity of heaters, kW | 1,98 | 5,28 | 5,28 | – |
6 | Rate capacity, kW | 5 | 8 | 13 | 8 |
6.1 | Power consumption without heating of kW/hour | 3 | 2,72 | 7,7 | 5 |
7 | Thickness of filters, micron | ||||
-input | 25(10) | 25(10) | 25(10) | 25(10) | |
-output | 5(3) | 5(3) | 5(3) | 5(3) | |
8 | Voltage of the three-phase alternating current main with a frequency of 50 (60) Hz, In | 380 | 380 | 380 | 380 |
9 | Overall dimensions, mm not more | ||||
-length-width-height | 2600/1400/2030 | 4800/1480/2140 | 6060/2590/2440 | 4800/1480/2140 | |
10 | Weight, kg not more | 1340 | 2550 | 5400 | 3400 |